Skip to product information
1 of 2

Solis Three Phase 30kW High Voltage Energy Storage Inverter - S6-EH3P30K-H-AU

Solis Three Phase 30kW High Voltage Energy Storage Inverter - S6-EH3P30K-H-AU

Please sign in to see pricing
  • 30kW three-phase hybrid inverter – for solar and high voltage battery storage
  • Three MPPTs, up to 60kW of PV – 40A per MPPT, 1000V maximum input, 150–850V MPPT range
  • Two battery ports – 150–800V, 70A per port, 140A combined charge current
  • 30kW backup output – rated at the full inverter output
  • 97.8% maximum efficiency – IP66, -25 to +60°C, up to 4000m
  • Australian compliant – AS/NZS 4777.2:2020
View full details
  • Description
  • Specifications
  • Downloads

Description

Overview

The Solis S6-EH3P30K-H-AU is a 30kW three-phase high voltage hybrid inverter from the Solis S6-EH3P(29.9-50)K-H-AU series, designed for three-phase solar and battery storage systems. The series covers 29.9kW to 50kW models.

Three MPPTs with 40A per tracker accept a PV array of up to 60kW. Two independent high voltage battery ports (150–800V) take 70A each, 140A combined, and the backup output is rated at the full 30kW.


Key Features

High PV Input Capability

  • Three MPPTs, 40A input current and 45A maximum short-circuit current per MPPT
  • Up to 60kW recommended PV array size with a 1000V maximum DC input
  • Wide 150–850V MPPT operating range

Battery & Backup

  • Two independent high voltage battery ports, 150–800V
  • 70A per port, 140A maximum charge current combined
  • 30kW backup output

Efficient & Robust

  • 97.8% maximum efficiency
  • IP66 enclosure for -25 to +60°C operation up to 4000m
  • 73kg, 530 x 880 x 290mm housing

Specifications

Model S6-EH3P30K-H-AU
Type Three Phase Hybrid Energy Storage Inverter
Topology Transformerless
AC phases Three
Maximum PV array power 60 kW
Maximum PV input voltage 1000 V
Nominal PV input voltage 600 V
MPPT voltage range 150 – 850 V
PV start-up voltage 180 V
Maximum PV input current per MPPT 40 A / 40 A / 40 A
Maximum PV short-circuit current per MPPT 45 A / 45 A / 45 A
Number of MPPTs 3
Number of PV string inputs 6
PV connection MC4 quick connection plug
Battery operating voltage range 150 – 800 V
Maximum continuous charge current 70 A × 2
Maximum continuous discharge current 70 A × 2
Maximum charge power 33 kW
Maximum discharge power 33 kW
Maximum charge / discharge power per battery input 33 kW
Battery connection Terminal connector
Number of battery inputs 2
Supported battery types Li-ion
Nominal AC input voltage 230 V / 400 V
Maximum AC passthrough current 86.6 A
Transfer (switch-over) time < 10 ms
Maximum generator input power 30 kW
Nominal AC output power 30 kW
Maximum AC apparent power 30 kVA
Nominal backup power (whole-home) 30 kW
Nominal AC output voltage 230 V / 400 V
Nominal AC output frequency 50 Hz
Nominal AC output current 43.3 A
Maximum AC output current 43.3 A
Power factor (adjustable range) > 0.99 (0.8 leading - 0.8 lagging)
Total harmonic distortion (THD) < 3 %
Peak backup apparent power 1.6 × rated power, 2 s
Maximum efficiency 97.8 %
European (weighted) efficiency 97.4 %
Standby / night consumption < 35 W
Maximum battery charge efficiency 98.5 %
Maximum battery discharge efficiency 97.5 %
Anti-islanding protection Yes (active frequency shifting)
Reverse polarity protection Yes
Short-circuit protection Yes
AC output over-current protection Yes
Surge protection (SPD) DC Type II / AC Type II
Integrated DC switch Yes
Arc-fault protection (AFCI) Optional
Communication interfaces CAN / RS485 / Ethernet / Wi-Fi (optional) / Cellular (optional) / LAN (optional)
Bluetooth Yes
Wi-Fi Optional
Ethernet Yes
Cellular (4G/LTE) Optional
Display 7.0" LCD display & Bluetooth + APP
Operating temperature -25 – 60 °C
Maximum relative humidity 95 %
Maximum altitude 4000 m
Protection rating (IP) IP66
Overvoltage category PV II / battery II / AC III
Dimensions (W × H × D) 530 × 880 × 290 mm
Weight 73 kg
Cooling Intelligent fan-cooling
AC connection Terminal block
Safety standards IEC 62109-1 / IEC 62109-2
EMC standards IEC 61000-6-2 / IEC 61000-6-4
Grid-connection standards AS/NZS 4777.2:2020
Maximum inverters in parallel 10 (Solis power distribution cabinet recommended above 6)

Downloads